New cell chemistries: high energy density, fast charging and excellent performance
Insight Mercedes-Benz Drivetrains & Efficiency: battery expertise
- Modular high-integration concept with compact battery design
- Premium battery version with up to 85 kWh usable energy capacity and silicon oxide anode
- Basic battery version with up to 58 kWh usable energy capacity and lithium iron phosphate cathode
- The most stringent Mercedes-Benz safety standards are met
Because cell chemistry essentially determines the performance of the battery, it is also ultimately the defining factor for the characteristics of the entire drivetrain. The VISION EQXX technology programme has demonstrated the importance of mastering cell chemistry for the development of future products. With its high-performance battery based on pioneering cell chemistry, it has set several EV track records. With its high energy density and fast-charging capability, the new battery generation is taking these successes to the next level. At the same time, the battery costs have been reduced by up to 30 %.
By developing the battery software in-house, Mercedes-Benz defined the brand's characteristic driving experience. Quality benefits from complete data transparency throughout the development phase. At the same time, the in-house approach underscores Mercedes-Benz's claim to be a leader in vehicle software.
Modular architecture and two battery types with different cell chemistries
The innovative battery system of the new Mercedes-Benz EV generation is based on a modular, high-integration concept. The repairable batteries comprise four large cell modules with hardcase cells and are characterised by a compact and flat design.
Customers will be able to choose between batteries with two different cell chemistries. The cells of the premium version with a usable energy content totalling 85 kWh have anodes in which silicon oxide is added to the graphite. Compared to the predecessor battery with conventional graphite anodes, the gravimetric energy density is up to 20 % higher. The volumetric energy density of the cell chemistry is 680 Wh/l. The proportion of cobalt has been further reduced.
This is followed by an all-electric entry-level variant with a lithium iron phosphate (LFP) cathode battery. The usable energy content there is 58 kWh and the volumetric energy density of the cell chemistry is 450 Wh/l.
Intelligent thermal management and comprehensive battery certificate
The high-voltage battery is integrated into the intelligent thermal management system of the all-electric MMA models to ensure that it always operates within an optimal temperature range, even in freezing cold or extreme heat. The system is equipped with a liquid cooling system, with an auxiliary heater integrated into the water circuit. At low temperatures, this heats up the cooling water, which then flows through the high-voltage battery, heating it and optimising its performance and efficiency range.
If Electric Intelligence navigation is activated, the battery is preheated during the journey if necessary. This preconditioning allows it to reach the optimum temperature at the fast DC charging point, which can charge the premium battery type at an output of 320 kW. This allows the battery to take on up to 36 kWh of energy within 10 minutes.
Despite a significant increase in charging capacity, the full scope of the battery certificate for the EQA and EQB model series still applies to the new all-electric entry-level models. Mercedes-Benz guarantees that the maximum battery capacity of the high-voltage battery will not fall below 70 % for a total of eight years or up to a total mileage of 160,000 km (whichever comes first).
Extensive safety measures
The battery housing is part of the vehicle structure and integrated into the collision safety concept. The battery, high-voltage (HV) cables and other HV components are designed and protected to meet the stringent safety standards of Mercedes-Benz in the event of an accident. In addition to the legal requirements, both the entire vehicle and the batteries must pass internal testing standards that are sometimes stricter.
In the pole impact test, one of the Group's own crash tests, electric vehicles are not only tested to ensure that the side structure offers maximum protection to occupants. It also examines the deformation behaviour of the battery. In this crash test configuration, the test vehicle on a sled crashes sideways against a steel pole. Mercedes-Benz uses another special test bench procedure to test the so-called touchdown management. This refers to the design precautions taken to prevent damage to the underbody caused by touching down, for example when driving over kerbs. During the test, a ram is pressed into the vehicle floor with a force of several tonnes. This also tests whether there is a risk of intrusion from foreign objects lying on the road, such as lost towbars.
Mercedes-Benz has further improved the already very high safety standard of the batteries with technical solutions for the new battery generation used in the MMA models. Comprehensive precautions have been taken against a potential thermal reaction of the battery through appropriate spacing between the battery cells and the structure of the cells and cell modules. In addition to alerting the occupants, the advanced early warning system in this model family includes other vehicle-side protective measures - for example, side windows and ventilation flaps close automatically. A new sensor positioned centrally in the battery monitors the batteries of Mercedes-Benz vehicles even when they are switched off.
Every battery is subjected to a pressure test at the end of production. The battery housings must also pass further tests. To verify comprehensive anti-corrosion measures, they are exposed to salt water, among other things.
The multi-stage protection concept of the HV system has already proven itself in other all-electric models from Mercedes-Benz. Analyses of real accidents by Mercedes-Benz Accident Research have also confirmed that safety in models with the three-pointed star is not a question of the drive concept. In the event of danger, the HV system can be automatically switched off and disconnected from the battery. A distinction is made between reversible and irreversible disconnection. Reversible disconnection takes place in the event of minor accidents. The high-voltage system can then be reconnected if an insulation measurement carried out by the vehicle beforehand does not detect a fault. This means that vehicles that are still roadworthy can continue to be driven. The high-voltage system is only irreversibly switched off in the event of serious accidents, in which the vehicle is usually no longer drivable anyway. It cannot be reactivated without repair in a specialised workshop. When the system is switched off, it ensures that no residual electrical voltage is present in the high-voltage system outside the battery within a few seconds. Disconnection points are also provided for the emergency services to deactivate the high-voltage system manually.
New centre of excellence for the development of high-performance cells, global production network
Mercedes-Benz recently strengthened its development activities in battery technology with the eCampus in Stuttgart-Untertürkheim. At this new centre of excellence, innovative chemical combinations and optimised production processes for high-performance battery cells with “Mercedes-Benz DNA” are being developed. The knowledge gained at the eCampus will flow into the technology development and series production of battery cells at the partner companies for use in future Mercedes-Benz battery generations.
The batteries for the all-electric Mercedes-Benz vehicles are manufactured in the global battery production network. The Kamenz battery factory will be the first factory in this network to produce batteries for the new MMA platform models. The cooperation with different cell suppliers worldwide follows the “local-for-local” approach.